Environmental Testing
Magna Parva's vacuum ovens are used for a wide variety of vacuum drying, curing and moisture content testing. Common applications include drying heat sensitive samples, moisture determination, drying samples within a controlled atmosphere. Operating features include;
- A temperature range of 5 degrees above room temperature to
250 degrees
-
A pressure range of 1000mbar to 2mbar
(abs)
- A PC based control system including Microprocessor PID
control, Auto-tuning and Calibration, thus enabling
thermal cycle testing of components with complete control.
- Large capacity of up to 65l
Clean Room Facility
Contained within our temperature and humidity controlled laboratory is an established clean room facility including;
- An ISO class 7 (10,000) modular clean room
- Zoned working areas achieving ISO class 5 (100)
- Particle Counters for ISO 14644 certification of Clean rooms enabling constant monitoring of particle levels
- Technicians trained in Planetary Protection and Bio-Burden control
Magna Parva utilises stringent component cleaning procedures in order to comply with space product assurance. Facilities include:
- Ultrasonic Baths for aggressive cleaning of components. All Baths include Industrial B.L.T. type ultrasonic transducers generating high-frequency sound waves.
- High temperature PID controlled vacuum oven enabling vacuum bake out of components for Dry Heat Sterilization and de-gassing.
Magna Parva's AIT Facilities can be made available for use to third parties. For further information and our full list of services please contact us.